Home › Guides

How to Read Sensor Specifications Correctly

Understand accuracy, precision, resolution, range, drift and other datasheet terms, and avoid the common mistakes when comparing sensors.

A sensor's datasheet is full of terms that sound similar but mean very different things. Misreading them is one of the most common reasons a sensing project underperforms. This guide explains the key specifications in plain language and shows how they fit together.

Range and span

The measurement range is the span of input values over which the sensor works as specified, for example from a lowest to a highest pressure. The span is the difference between the two ends. Operating outside the range may give wrong readings, and exceeding the stated overload or absolute maximum limits can damage the device permanently. Note that the operating temperature range of the sensor itself is a separate figure from the range of the quantity it measures.

Accuracy, precision and resolution

These three words are often mixed up.

  • Accuracy describes how close a reading is to the true value. It is usually written as a plus-or-minus figure, either in measurement units or as a percentage of the reading or of full scale.
  • Precision, often called repeatability, describes how closely repeated readings of the same unchanged input agree with each other.
  • Resolution is the smallest change the output can represent. A display showing two decimal places does not mean the sensor is accurate to two decimal places.

A sensor can be precise but not accurate, giving tightly grouped readings that are all offset from the truth. It can also have fine resolution and poor accuracy. High resolution never guarantees correctness.

Percent of reading versus percent of full scale

An accuracy of one percent of full scale means the allowed error is a fixed amount across the whole range. On a sensor with a range of 0 to 100 units, that is plus or minus 1 unit even when you measure 5 units, which is a 20 percent error at that point. An accuracy given as a percentage of reading scales with the value. Always check which basis the datasheet uses before comparing devices.

Linearity, hysteresis and repeatability

Linearity tells how closely the output follows a straight line against the input. Hysteresis is the difference in output when the same input is approached from above versus from below. Repeatability covers variation between identical measurements under the same conditions. They are usually reported as small percentages and contribute to the total error.

Drift and stability

Drift is a slow change in output over time while the input stays constant. It can be caused by ageing materials, temperature changes or contamination. Datasheets may state long-term stability per year, or temperature coefficients such as the offset change per degree. Drift is the reason sensors need periodic checking, covered in sensor calibration basics.

Response time and noise

Response time describes how quickly the output follows a change in input, often given as the time to reach a stated fraction of a step change. Noise is random variation in the output. Averaging several readings reduces noise but slows the response, so the two needs must be balanced.

Other values worth noticing

TermWhat it tells you
SensitivityHow much the output changes per unit of input
OffsetOutput when the input is zero
Supply voltagePower requirement and compatibility with your electronics
Output typeAnalog voltage or current, or digital interface
Ingress protection and materialsSuitability for moisture, dust or chemicals

Total error is more than one number

The accuracy figure in a datasheet is sometimes only one contributor to the overall error you will see in practice. A complete error budget adds up the effects of offset, gain error, non-linearity, hysteresis, temperature coefficients, drift and the resolution of the converter that reads the sensor. Some of these can be combined as a root-sum-square when they are independent, while others, such as a fixed offset, simply add. If a datasheet gives a worst-case figure, it is safe to plan around it; if it gives a typical figure, expect some units to be worse.

Typical versus guaranteed values

Many tables list typical, minimum and maximum columns. Typical values describe what a normal unit does under ideal conditions, while minimum and maximum values are limits the manufacturer stands behind. Design to the limits, not the typical column, whenever correct operation depends on the figure.

Tip: Read the conditions printed next to each figure. Accuracy is often stated only at one temperature or supply voltage, and may be much worse across the full operating range.

Putting it to use

When comparing candidates, convert every accuracy figure to the same basis and check it covers the conditions you will really face. For a broader decision process, continue with choosing a sensor, and see types of sensors if you are still deciding which family fits.